Inspection History Details
Inspection Status: Partial Approval
Inspection History: FRAMING
Permit Number - T97CM02392
Inspection Description - FRAMING
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/14/1997 | FRAMING | Partial Approval | FRONT RM OK TO DRYWALL | |
09/27/1997 | FRAMING | Correction Required | ADDTL COMMS - 1. FIRE BLKS MISSING AT FURNACE ROOM AT DROP. 2. STAPPLE WIRE AWAY FROM FURN. FLUE. 3. 2 ANCHOR BOLTS REQUIRED PER PLATE MIN AT INTERIOR BEARING WALLS IN GARAGE. 4. CLIP K STUD TO SILL AT BOTH SIDES. 5. CLIP FLOOR JOIST TO BEARING WALL. 6. BLOCK REGISTER VENTS MIN 3 WAYS. 7. # 10 MIN PRESSURE ON GAS LINE TEST BOTH SIDES. | |
09/27/1997 | FRAMING | Denied |