Inspection Status: Not ready for Inspection
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/24/2000 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 12/01/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - 1. PAINT AND SEAL EXTERIOR OF HOUSE. 2. PROVIDE CAP AND COVER FOR KITCHEN SINK CLEAN OUT. 3. GARAGE SELF CLOSING DOOR NOT WORKING. 4. INSULATION CERTIFICATE AT FINAL. |
| 12/01/1999 |
BUILDING - FINAL |
|
Partial Approval |
PARTIAL APPROVAL |
| 11/29/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - 1. PROVIDE COVER/SEAL FOR CLEAN OUT AT KITCHEN. 2. GFCI AT FRONT NOT WORKING. 3. SEAL ALL EXTERIOR PENETRATIONS. 4. LABEL ELECTRIC PANEL AND TIGHTEN ALL NEUTRALS AND GROUNDS. 5. GFCI IN GARAGE NOT WORKING. 6. COVER CLEAN OUT IN GARAGE. 7. SELF CLOSING DOOR NOT WORKING AT GARAGE. 8. SECURE DRAFT HOOD ON HOT WATER TANK. 9. PROVIDE SMOKE DETECTOR IN HALL WAY, CHECK DETECTOR IN ENTRY. 10. TIE DISHWASHER LINE TO FLOOD RIM OF SINK. 11. COMPLETE DISPOSAL. 12. PATCH HOLE BEHIND STOVE, PROVIDE ANTI TIP, AND COMPLETE ELECTIC BEHIND STOVE. 13. PROVIDE MIN. 1-0 CLEARANCE FROM ROOF TO TOP OF TYPE B FLUE. (FOR HEATER AND WATER AT ROOF). |
| 11/29/1999 |
BUILDING - FINAL |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |