Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/29/2002 |
FRAMING |
|
Approved |
|
| 12/10/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 04/26/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - WEST END 5 EACH 2 X 12 RAFTERS CANNOT BE SUPPORTED BY A 4 X 6 BEAM IN THE FLAT SPANNING 9. RAFTER LENGTH 21 OR BUILD BEARING WALL PER PLAN. WINDOWS AND DOORS REQUIRE DOUBLE 2 X 6 HEADERS IN VERTICAL - PRESENTLY SINGLE 2 X 6 IN FLAT. LAUNDRY TRAPS NOT IN. SUPPORT PLBG 4 O.C. H25 CLIP RAFTERS. |
| 04/26/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 04/21/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - NOT READY FOR EITHER INSPECTION-COMPLETE ALL FRAMING BE ADVISED: 1. THE BRICK VENEER WAS COMPLETED WITHOUT INSPECTION OF THE BRICK TIES TO SUPPORTING WALL. 2. NOTCHING OF THE 2X12 RAFTERS AT THE BEARING ENDS REDUCES THE RAFTER TO THE ACTUAL WIDTH OF THE BOARD AT THE BEARING POINT. SEE YOUR FRAMING DETAIL 1-4. YOU WILL HAVE TO REPLACE THE RAFTERS BECAUSE ALL HAVE BEEN CUT. |
| 04/21/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0950* |