Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/09/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - BUILDER WAS NOTIFIED ON PREVIOUS INSPECTION OF MISSING SUPPLY AIR REGISTER IN DINING AREA. IT IS ASSUMED THAT BUILDER WISHES TO PROCEED WITHOUT SAID VENT. |
| 03/05/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. THE USER OF FLATTEND A2.5 STRAPS TO STRAP THE HEADERS TO THE TRIMMER AND KING STUD IS IMPROPRE. USE 2 NAIL LINE CS OR CST STRAPS ( MAY BE APPLIED TO INSIDE EA. SIDE). A 2.5 STRAPS ONCE FLATTENED HAVE NO LISTED UPLIFT VALUE AND ARE NOT A LISTED PRODUCT. 2. THE A35 STRAPS REQUIRE 12 8D NAILS ALL ARE UNDER NAILED. 3. THE A2.5 STRAPS ARE UNDER NAILED- SEE MFGRRS INSTRUCTIONS. 4. THE A 2.5 STRAPS NAILED FROM CENTER WALL TOP PLATES TO TJI TRUSSES REQUIRE THE USE OF WEB STIFFNERS- CORRECT ALL. 5. THE SUPPLY AOR REGISTERS TO DINING ROOM IS MISSING. 6. THE SUPPLY AIR REGISTERS REQUIRE 3 SIDES BLOCKED. CORRECT AND RECALL |
| 03/05/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |