Permit: T97CM01840

Parcel: 137275640


Addresses:

1500 W NEVINS DR

Inspection Status: Closed

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/06/2008 BUILDING - FINAL Closed OK AS OFFICES.
01/10/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) BEDROOM ON EAST SIDE IS OK FOR MINIMUM REQUIREMENTS
2) BEDROOM ON WEST SIDE EMERGENCY EGRESS WINDOW MUST HAVE MINIMUM AREA, PLUS 20" WIDE X 24" HT YOUR WINDOW IS 21" X 36" = APPOX 4.5 SQ FT YOU NEED 5.7
3) CANNOT LOCATE CIRCUIT BREAKER FOR POWER SOURCE FOR NEW ROOMS, RECEPTS TEST OUT OK PERMIT TAKEN OUT 6/28/97 ARC FAULT REQ. NOT IN ELECTRIC
4) PLEASE HAVE A SERVICE LOAD CALCULATED, A/C ADDED, PLUS H20 HTR CONVERTED FROM GAS 125 AMP SERV. MAX
5) YOU CAN HAVE BEDROOMS REMOVED FROM PERMIT AND CHANGED TO OFFICES
6) FOR FINAL ONLY/BUILT WITHOUT PERMITS OR INSPECTIONS
10/17/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SEE NOTES FROM 1997
2. PROVIDE ACCESS
3. PROVIDE CORRECT CONTACT INFORMATION

1154 AM
07/31/1997 BUILDING - FINAL Correction Required ADDTL COMMS - WATER HEATER LOCATED IN BEDROOM. PLMBG. CODE SEC. 802 PROHIBITS GAS WTR. HEATER IN SLEEPING ROOMS.
07/31/1997 BUILDING - FINAL Denied