Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/17/2003 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 03/07/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) LEAK AT WAHSER TRAP-IF THREADED TRAP IS USED, MUST HAVE ACCESS PANEL. COULD BE CHANGED TO GLUE TRAP |
| 03/03/2003 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 05/21/2001 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ALL BUT GAS LINE |
| 11/27/2000 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0350*/NOTE: WASHER AND TUB SHOWER OK COPPER OK. 1. 1 1/2" TRAP ARM TO LAV. CANNOT EXCEED 42" PRESENTLY NOT INSTALLED YOU MAY USE 2" UP TO 60 INCHES OR RE VENT 1 1/2". 2. WATER CLOSET FLOOR FLANGE NOT INSTALLED. 3. NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD SURFACES. 4. BACK GROUT FLOOR PENETRATE. |
| 06/05/2000 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/1. NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD SURFACE COPPER PLUMBING AND UNION OK. |