Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T97CM01696

Parcel: 116092770


Addresses:

566 N SHANTEL DR

Inspection Status: Denied

Inspection History: FRAMING

Date Description Inspector Results Comments
11/17/1997 FRAMING Denied SEE LAST WRITE-UP
11/13/1997 FRAMING Correction Required ADDTL COMMS - 1. DRAFT STOP @ FIRE PLACE. 2. LOOSE STRAPS @ FIRE PLACE FLUE. 3. GABLE END BRACING PER 11/D1 17/D1. 4. DRAFT STOP @ BED ROOM POP OUT. 5. MISSING RED HEADS OR A.B. NUT & WASHER.
11/13/1997 FRAMING Denied DENIED