Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/07/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. SEAL F/P CHACE AT CEILING AND INSTALL ASH GUARD NEED PROOF OF ROOF FRAMING INSPECTION. STOPPED INSPECTION. |
| 08/07/1998 |
FRAMING |
|
Denied |
DENIED |
| 08/03/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. NEED F/P SPECS ( RE COMBUSTABLE AGAINST CHIMNEY). 2. NEED TRUSS DRAWINGS W/ALL HARDWARE, HANGERS REQUIRED. 3. MISSING H2.5S AT TRUSSES. 4. J BOXES TO BE ACCESSABLE. 5. GROUND RECPS. 6. NEED TO INSPECT FIRE PLACE. 7. RECP FOR TUB. 8. FIRE BLOCK ALL CONCEALED AREAS. 9. GROUT TUB BLOCK OUTS. 10. A C DISCONNECT. 11. CLEAN UP ALL WIRING. 12. EXPOSE F/P AT MASTER . 13. NEED RECP FOR EACH VANITY. 14. CHECK FOR BANG PLATES. STOPPED INSPECTION. |
| 08/03/1998 |
FRAMING |
|
Denied |
DENIED |
| 11/04/1997 |
FRAMING |
|
Partial Approval |
BAY WINDOWS ONLY |