Inspection Status: Correction Required
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 01/27/1999 |
ELECTRIC - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. NEED C/O FOR WASHER LOWER THE TRAP. 2. ISOLATE WITH TO DISSIMILAR METAL. 3. COMB/RELIEF DUCT 100 SQ EACH. 4. NEED GAS VENTS. 5. PLENIUM FOR RETURN AIR. 6. NEED C.O AT (KITCHEN SINK). 7. 2 20 AMP COUNTER TOP CIRCUITS. 8. H2O BOND AND GAS LINE USE #6. 9. NEED DROP CEILING. 10. PRESSURE TEST GAS LINE. ( LINES OKAY FOR SIZE). 11. ALL BATHROOM GFCI TOO BE ON 20 AMP CIRCUIT. |
| 01/27/1999 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |
| 11/05/1998 |
ELECTRIC - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - TIE ALL GROUNDS IN BOXES |
| 11/05/1998 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |