Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/18/1997 |
FRAMING |
|
Correction Required |
ADDTL COMMS - REVISE SITE PLAN TO SHOW EXISTING STG BLDG. |
| 07/17/1997 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. A.B. MISSING @ INT BEARING WALL, 2. CLIP JOISTS TO TOP PLATE INT. BEARING WALL - ALL 3. CLIP HEADERS TO KING STUDS INT. BEARING WALL. 4. FIREBLOCK PLBG WALL AT CEILING. 5. ADDRESS ELEC PANEL. 6. FIREBLOCK MISSING IN COLD AIR RETURN CHASE. OK TO CLEAR C/D TS. NOTE - NO PERMITS HAVE BEEN OBTAINED FOR APPROX 14 X 14 STG BLDG AT REAR OF PROPERTY. NO FINAL INSP WILL BE GRANTED UNTIL PROPER PERMITS OBTAINED. |
| 07/17/1997 |
FRAMING |
|
Denied |
|