Permit: T97CM00472

Parcel: 128031560


Addresses:

5622 E WHITTIER ST

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
09/16/1997 FRAMING Correction Required ADDTL COMMS - NEED LETTER FROM LUMBER CO. CONCERNING GILA LAM BM IN GARAGE BEFORE FINAL.
09/09/1997 FRAMING Correction Required ADDTL COMMS - 1. FIRE BLOCK TOP OF FIRE PLACE CHASE. 2. ADD A STUD @ HEAD OF SHOWER TO REDUCE CENTERS. 3. ROOF NOT FRAMED PER PLANS ALSO GARAGE HEADER 4. HEADERS NOT BEARING. 5. NAIL CORNERS N. E. SHOWEER. 6. NAIL TOP PLATE OF MASTER CLOSET TO LADDER BLOCKING. 7. HAVE LUMBER COMPANY SUBMITT LETTER OF ACCEPTANCE FOR GLU-LAM CRACK OVER GARAGE. 8. H2.5 THR FLY RAFTER @ KITCHEN WALL. 9. TIE DOWN EAST END OF LIVING ROOM GLU-LAM. 10. PROVIDE VENTED FRIEZE BOARDS @ EAST END OF MASTER BED ROOM.
09/09/1997 FRAMING Not ready for Inspection SEE NOTES