Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/21/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - PROBLEM SAME AS 1025 3/26/97 AND 2035 03/26/97 (NO PLANS OR PERMITS ON SITE). SEND VIOLATION NOTICE IF NOT REPAIRED IN 15 DAYS. |
| 09/21/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |
| 03/26/1997 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1.UNTREATED WOOD CANNOT BE WITHIN 6 OF SOIL, YOU MUST INSTALL COMBUSTION AIR RELIEF FOR FURANCE COMBUSTION, IT MUST INCLUDE 100 SQ IN WITHIN 12 OF CEILING AND 100 SQ IN WITHIN 12 OF FLOOR, WATER HEATER PRV LINE MUST EXHAUST OUTSIDE |
| 03/26/1997 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
|