Inspection Status: Correction Required
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/15/1997 |
SHEET ROCK NAILING |
|
Correction Required |
ADDTL COMMS - 1. THE DRYWALL SHEETS HAVE BEEN INSTALLED IN A RAILROAD CONFIG- THAT IS ALL SEAMS ARE PARALLEL. SEAMS MUST BE OFFSET. TO ADD STRENTGH TO CEILING/ROOF FRAMING. SCREWS BE SET AT 16 SCREW TO SCREW ON WALLS AND 12 SCREW TO SCREW ON CEILING. REDO. 2. GASLINE UNDER SLAB MUST BE ABANDONED AND ALL PIPING ROUTED THRU WALL OR CEILING TO ITS FINAL DESTINATION. 3. THE CLOTHES WASHER AND VENT PIPE MUST BE 2 MIN AND A CLEAN OUT INSTALLED IN THE DRAIN SIDE. |
| 12/15/1997 |
SHEET ROCK NAILING |
|
Denied |
|