Inspection History Details
Inspection Status: Correction Required
Inspection History: POOL/SPA PRE-GUNITE
Permit Number - T97BU02318
Inspection Description - POOL/SPA PRE-GUNITE
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/21/1998 | POOL/SPA PRE-GUNITE | Correction Required | ADDTL COMMS - MOVE BOND BEAM FORM @ EAST END TO INCLUDE BOND BEAM STEEL | |
01/15/1998 | POOL/SPA PRE-GUNITE | Not ready for Inspection | ||
01/12/1998 | POOL/SPA PRE-GUNITE | Correction Required | ADDTL COMMS - 1. EXC. & FORM A BOMD @ EAST END. 2. PROVIDE A #2 CONT.,HORIZONTIALLT @ THE INTERSECTION OF THE WALL AND THE FLOOR. OR PROVIDE A DETAIL OF THE EAST END OF THE POOL BY THE ENGINEER OF RECORD AND APPROVED BY THE CITY PLAN CHECKER. | |
01/12/1998 | POOL/SPA PRE-GUNITE | Not ready for Inspection | SEE NOTES | |
01/02/1998 | POOL/SPA PRE-GUNITE | Correction Required | ADDTL COMMS - 1. PROVIDE A BOND BEAM @ POOL PERIMETER @ EAST END. 2. PROVIDE A #3 CONTINIOUS HORIZONTALLY @ THE JUNTURE OF WALL & FLOOR @ THE EAST END, OR PROVIDE A DETAIL OF THE EAST END OF THE POOL BY THE ENGINEER OF RECORD AND APPROVED BY CITY PLAN CHECK. | |
01/02/1998 | POOL/SPA PRE-GUNITE | Denied | SEE NOTES | |
12/18/1997 | POOL/SPA PRE-GUNITE | Correction Required | ADDTL COMMS - 1. POVIDE APP. PLANS. 2. COMPLETE STEEL @ SKIMMERS.3. COMPLETE STEEL @ LIGHTS. 4. HAVE THE EAST END OF THE POOL DETAILED ON THE APP. PLANS. THE STEEL APPEARS INCOMPLETE. | |
12/18/1997 | POOL/SPA PRE-GUNITE | Denied | SEE NOTES |