Inspection Status: Correction Required
Inspection History: POOL/SPA ELECTRIC
| Date |
Description |
Inspector |
Results |
Comments |
| 12/12/1997 |
POOL/SPA ELECTRIC |
|
Correction Required |
ADDTL COMMS - 1. INSTALL WIRE PROTECTOR BUSHING AT SPA CONTROL BOX. 2. FLEX NON METALIC CONDUIT CAN NOT RUN UNDERGROUND. 3. INPROPER SPLICE ON NEUTRAL WIRE TO SPA. 4. YOU MUST HAVE SEPARATE ISOLATED NEUTRAL ADN GROUND BARS AT SUB PANEL. |
| 12/12/1997 |
POOL/SPA ELECTRIC |
|
Denied |
DENIED |
| 12/04/1997 |
POOL/SPA ELECTRIC |
|
Correction Required |
ADDTL COMMS - POOL ELEC CONNECTED TO AN UNSAFE ELEC SUB PANEL. DISCONNECT FROM THIS PANEL ALL POOL CIRCUITS. OK TO GUNITE. |
| 12/04/1997 |
POOL/SPA ELECTRIC |
|
Partial Approval |
PARTIAL APPROVAL |