Permit: T97BU01632

Parcel: 116012660

Inspection Status: Correction Required

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
02/13/1998 ROOF NAILING Correction Required ADDTL COMMS - ROOF IS COMPLETELY COVERED - ROOF NAILING OK
10/30/1997 ROOF NAILING Correction Required ADDTL COMMS - YOU HAVE INSTALLED POST, BUT YOU NEED TRIM STUDS AT THE WINDOWS, ALSO YOU NEED A HEADER & CRIPPLES AT DOOR, NO PLANS OR PERMIT ON JOB, TO INSPECT ROOF NAILING, I MUST SEE IT BEFORE YOU INSTALL ROOF PAPER, WHAT DO YOU HAVE FOR BOLTS ON EAST WALL PLATES? PLEASE CALL FOR INSPECTION
10/30/1997 ROOF NAILING Denied
10/24/1997 ROOF NAILING Denied SEE LAST INSP
10/22/1997 ROOF NAILING Correction Required ADDTL COMMS - ROOF SHEATHING NAILING AT EDGE & ENDS SHOULD BE 6 O.C., 2 X 10 RIDGE IS BUTT JOINT IN MIDDLE - WILL NEED POST OR SPLICE WITH ANOTHER 2 X 10 NAIL OR BOLTED - SEE PLAN CHECKER FOR APPROVAL
10/22/1997 ROOF NAILING Denied DENIED