Inspection History: TRSP - ROW - Recurring

Permit Number - T22RW00251

Inspection Description - TRSP - ROW - Recurring

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/28/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar dropped in Sauna tube. Placing 2x4s and plywood along back. Placing plywood and ada wall. Dropping rebar cage in. Removing leftover material and placing plate over sidewalk with cold patch.
03/29/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/28/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar finished hole with auger. Will drop forms and frame for pole caisson. Remove excess material and plate on top of hole.
03/28/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/24/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar removed spread footing. Will continue to trench for new caisson for swf. Plate to be placed over sidewalk at end of night. James deih staying onsite until crew is finished.
03/28/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan. Requested contractor call trafficade for sandbags. Barricades blown over
03/24/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar exposed edges of spread footing. Big fiber path running directly online with sidewalk under spread footing. Checking to see if fiber poured into footing or under footing to remove caisson.
03/24/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/24/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar and James deih onsite for pole and caisson removal. Per direction of Northstar trafficade closed both north bound lanes on Euclid and channeled traffic into center “suicide” lane. Last night when discussed I told them specifically that was not aloud and not on approved MCP. Traffic very heavy due to UA basketball game and university blvd closed for block party. Crane rigging went into second north bound lane. Told them to get the pole removed and open traffic immediately. Until MCP is submitted and approved for double lane closure contractor and trafficade must abide by approved plans. Notified Dan Robertson COT of the issue.
03/24/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/23/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar vacuum trenching around caisson for removal. Dropping 4” conduit in trench from last night for fiber run. Gave permission to backfill under sidewalk with concrete due to slurry being over a week out. Rest of trench will be native backfilled with visual processing and compaction inspection. James deih onsite for work being done.
03/23/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/23/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar finished trenching for fiber conduit. Trench verified at 41” for 4” fiber conduit being dropped in tomorrow night. Sand bags placed around native piles. Ply wood placed over trenches with ada wall surrounding. Saw cuts mad in side walk on Euclid for demo tomorrow night. Work done for night cleaning up.
03/23/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/22/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar trenching west along north side of sidewalk to future swf site. Upon excavation for trench tooth of excavating machine caught the sidewalk panel and loosened two panels. Panel now has 1/4”-1/2” kicker. Both panels will need replacement. Home owner near site said we needed to be done by 2200 and Northstar notified her of TNE and night work hours on permit. Homeowner was notified 5 days prior to construction beginning. Sam deih left site around 2130-2200 after construction was underway.
03/22/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
08/25/2022 TRSP - ROW - Recurring Passed TDOT-EXCAV GENERAL INSPECTION - Northstar completed work. Landscaping and sidewalk restored. Site passes final ROW inspection
05/20/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Pour completed and finishing being done. Crew appears to struggle some with speed of concrete setting up. Water being sprayed on top to finish and smooth surface. Rocks in mix appeared to cause issues with score joints but was fixed. Will check concrete restoration Monday with ten foot straight edge for deviations.
08/25/2022 TRSP - ROW - Recurring Passed TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site.
05/20/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Quail restoration and Northstar restoring sidewalk with in demand concrete mix. Mix set to 3000 psi. Material appears to set quickly. Walkable and hardened within 30 minutes. Appear to have a gap near top near swf pole. Will check Monday with straight edge. Did not allow them to fill gap as concrete was already setting. Concrete temp was 82°f. Slump appeared loose even though a quick set up.
05/20/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/30/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Sam k onsite. Sent pictures of traffic control. Locators came to site and determined telephone lines were abandoned. Northstar placed plate and will be back for concrete next week.
05/20/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/29/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar placing conduit. Waiting for locators to come discuss lines found last night. James deih onsite.
03/30/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/29/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar cleaned up and set plate. Set Ada wall around site. Rebar cage installed. Plywood secure under ada wall. Will stay onsite for trafficade take down. Site is secure and accessible for pedestrians. Sand bags placed around material stockpile.
03/29/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/29/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Upon removing concrete around city electric box exposed fiber was found while digging. Fiber had tape or heat shrink around it. Contractor leaving open to see who’s fiber it is and what they want done with it. Fiber is not marked on either side by blue stake.
03/29/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
03/22/2022 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Northstar onsite to trench for 4” fiber conduit. Trench will be left open until tomorrow night when pipe is installed and filled. Trench must be covered and ada wall placed around. Saw cut sidewalk panels around site for construction crew tomorrow night.
03/22/2022 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control needs maintenance not set according to plan. Trafficade setting to plan.