Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Passed
Inspection History: COT - ENGR - Signage Final
| Date |
Description |
Inspector |
Results |
Comments |
| 08/30/2022 |
COT - ENGR - Signage Final |
Hthrall |
Approved |
Entered by HTHRALL1 - Engineered plans were reviewed / approved by Juan Garcia 8/29/22. |
| 08/04/2022 |
COT - ENGR - Signage Final |
hthrall1 |
Partial Approval |
Entered by HTHRALL1 - revised plans submitted / also awaiting structural review of engineered plans |
| 08/03/2022 |
COT - ENGR - Signage Final |
hthrall |
Partial Approval |
Entered by HTHRALL1 - RE: sign permit review
For: 4 freestanding sign structures (6 signs total, 2 co-locations)
AT: 5255 E Williams Cl / Williams Centre
Zoning: PAD-1
Sign permit: T22OT00536
Reviewer: H. Thrall
Date: 8/3/22
** MASTER SIGN PROGRAM MSP-22-07 / T22SA00317**
PERMIT STATUS: PARTIAL APPROVAL
Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC 600), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018
1. UDC:
a. Site plan sheet for Signs A and B has odd dimensions on it referencing 8.6 and 3.5 feet - but clearly not to the points noted, remove or adjust these notes. Understood sign setbacks are met and out of the 20' deep easements on the property that extend 20' deep into the site.
2. NEC / OLC
a. Provide note that timer shall be shut off at midnight for all structures.
b. Show shut off switch and provide lockout - all sign structures.
c. The side blue light on the section detail is shown exposed, provide cover to enclose the light to meet outdoor lighting code and label the cover. Ok if translucent, just no direct visibility of the bulb.
d. Enlarge electrical detail for signs C-F - cannot read all the information clearly
3. IBC
a. Cross-section of Sign A and B do not match the proposal with raised lettering on the sign surface, revise and show method of attachment or mounting for the raised lettering
b. Provide engineering for these sign structures for review
c. Note that on site welds require special inspections.
Return revisions to Heather.Thrall@tucsonaz.gov
|
| 09/08/2022 |
COT - ENGR - Signage Final |
Hthrall |
Continued |
Entered by HTHRALL1 - DO NOT FINAL UNTIL SPECIAL INSPECTIONS VERIFIED - ON SITE WELDS AND OR HI STRENGTH BOLTS. |