Permit: T22OT00378

Parcel: 10601229D


Addresses:

3619 N 1ST AV

Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
06/20/2022 COT - ENGR - Signage Final hthrall Approved Entered by HTHRALL1 -
06/15/2022 COT - ENGR - Signage Final hthrall Continued Entered by HTHRALL1 - Revised construction diagram / elevation view submitted 6/15.
06/13/2022 COT - ENGR - Signage Final Hthrall Partial Approval Entered by HTHRALL1 - Revision received 6/10/22 reviewed 6/13/22 Status: Partial Approval Please address the following on the elevation view of the plans: RE: sign review For: new monument sign with digital message center AT: 3619 N 1st Avenue Sign Permit: T22OT00378 Reviewer: H. Thrall Date: 5/23/22 (2nd review 6/13/22) Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC 600), Tucson Pima County Outdoor Lighting Code (OLC), and International Building Code (IBC). 1. OLC: a. The OLC requires a timer for each sign, understood the units you're working with have a built in system . Provide an on site timer as back up, set to midnight curfew, for inspection. 2. IBC: a. provide notations how all angle iron is attached on the sign "skirting" and to support pole, and to sign cabinet (EMC). b. provide clarification note that "re-using existing freestanding sign support pole and footer" c. provide notation how aluminum pole cover is mounted to angle iron d. provide size of bolts and number of bolts to be used for saddle mount Please send revisions to Heather.Thrall@tucsonaz.gov
06/10/2022 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - Revision received 6/10/22. Items 2-4 from last review were not addressed, appears that some pages were left off the resub. Sent the review comments to the contractor to address. RE: sign review For: new monument sign with digital message center AT: 3619 N 1st Avenue Sign Permit: T22OT00378 Reviewer: H. Thrall Date: 5/23/22 (Revision reviewed 6/10/22) Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC 600), Tucson Pima County Outdoor Lighting Code (OLC), and International Building Code (IBC). 2. NEC: (Not addressed) a. explain the power source to the sign - is it existing with a permit or does it require electrical permit still? b. note location of the dedicated circuit and labeled breaker panel c. provide the volts, amps, and circuits for the sign on the elevation view 3. OLC: (Not addressed) a. acknowledged sure fire sign letter, thank you. Clarify on plan sheet view what the method is to dim the sign to 200 NITS (i.e. laser sensor?) and the location of it on the sign (i.e. on the side of the cabinet?) b. add note that the sign shall not exceed 200 NITS light brightness from sunset to midnight curfew c. add note the EMC unit is a master and mirror to present same message on each side simultaneously d. add note the unit is full color and shall not exceed 4400k color temperature light brightness at any time (including daytime) for an internally illuminated sign e. add note for the timer location f. add note the sign shall shut off at midnight curfew via timer 4. IBC: (not addressed) a. provide notations how all angle iron is attached on the sign "skirting" and to support pole, and to sign cabinet (EMC). b. provide clarification note that "re-using existing freestanding sign support pole and footer" c. provide notation "no field welds" d. given "v formation", call out location of the support pole on the "V" diagram, and clarify how each side of the sign will be mounted to the support pole. e. is there a "backer" between the cabinets as well or is this area just open? f. ID the "box" shown in the "V formation" view Please send revisions to Heather.Thrall@tucsonaz.gov
05/23/2022 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - RE: sign review For: new monument sign with digital message center AT: 3619 N 1st Avenue Sign Permit: T22OT00378 Reviewer: H. Thrall Date: 5/23/22 Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC 600), Tucson Pima County Outdoor Lighting Code (OLC), and International Building Code (IBC). 1. UDC 7A: a. The site qualifies for the sign, based on the overall site frontages off each Prince and 1st Avenue, per prior discussion. For the permit record, please provide an aerial overview of the entire site with the street frontages measured along both Prince Road and 1st Avenue. b. provide sight visibility triangle at the street corner, measured 20' into the site either from the curb or from the white line of travel lane (Admin Manual 10-05) and at 345' long heading west away from the site (understood it would go past the site, provide it to scale on the page and note the plan scale) c. ID the location and the number of freestanding signs on the site, and their pending removal. d. on the site plan, note the location of the sign is in a vehicle display area (not parking area) and provide any bollards or curbing that may be needed to protect the sign 2. NEC: a. explain the power source to the sign - is it existing with a permit or does it require electrical permit still? b. note location of the dedicated circuit and labeled breaker panel c. provide the volts, amps, and circuits for the sign on the elevation view 3. OLC: a. acknowledged sure fire sign letter, thank you. Clarify on plan sheet view what the method is to dim the sign to 200 NITS (i.e. laser sensor?) and the location of it on the sign (i.e. on the side of the cabinet?) b. add note that the sign shall not exceed 200 NITS light brightness from sunset to midnight curfew c. add note the EMC unit is a master and mirror to present same message on each side simultaneously d. add note the unit is full color and shall not exceed 4400k color temperature light brightness at any time (including daytime) for an internally illuminated sign e. add note for the timer location f. add note the sign shall shut off at midnight curfew via timer 4. IBC: a. provide notations how all angle iron is attached on the sign "skirting" and to support pole, and to sign cabinet (EMC). b. provide clarification note that "re-using existing freestanding sign support pole and footer" c. provide notation "no field welds" d. given "v formation", call out location of the support pole on the "V" diagram, and clarify how each side of the sign will be mounted to the support pole. e. is there a "backer" between the cabinets as well or is this area just open? f. ID the "box" shown in the "V formation" view Please send revisions to Heather.Thrall@tucsonaz.gov
12/12/2022 COT - ENGR - Signage Final Passed