Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T22OT00319

Parcel: 13409018F


Addresses:

8640 E BROADWAY BL

Inspection Status: Complete (Recurring)

Inspection History: COT - ENGR - Signage Final

Date Description Inspector Results Comments
05/19/2022 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - emailed contractor, appears missing data layer on plans
05/19/2022 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - Resubmittal received 5/18/22
05/04/2022 COT - ENGR - Signage Final Hthrall Partial Approval Entered by HTHRALL1 - RE: sign permit review For: wall signs and change copy on pole sign At: 8640 E Broadway / Walmart Market Sign permit: T22OT00319 Reviewer: H. Thrall Date: 5/4/22 Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC) 600, Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1. UDC: A) Total sign area should be noted on each sign, including change copy panels 2. NEC: A) provide lock out switch on back of sign at powerpack for safe work on sign B) indicate where the dedicated breaker panel is located for inspections, ensure labeled 3. OLC: A) note location of timer (i.e. corporate timer?) B) clarify if business is 24 hour or if timer needs to be set to midnight 4. IBC: A) note mounting method to the power pack to the back of the wall (sign A, B, E) Please return revised plans to Heather.Thrall@tucsonaz.gov
06/10/2022 COT - ENGR - Signage Final Hthrall1 Continued Entered by HTHRALL1 - Your sign package has been authorized for a self-certification inspection. (8 or less signs, and all attached to a building) Either schedule 09830 as a remote video inspection by leaving your date desired, and then include in the message your phone number and email address OR Email PDSDsigninspections@tucsonaz.gov pictures of the following items to conduct the self-certification inspection: Elevation view of installed signs to match approved plans Angled pic of sign lettering to contain the UL sticker in install sticker Shut off switch labeled breaker panel - clearly ID signs, ID business location in pic breaker panel switches in "on" position for signs Pic of timer - ID shut off time set to, and ID business location in pic Note that a lock out may be required, depending on location of shut off and location of sign.