Inspection Status: Complete (Recurring)
Inspection History: COT - ENGR - Signage Final
| Date |
Description |
Inspector |
Results |
Comments |
| 05/19/2022 |
COT - ENGR - Signage Final |
Hthrall |
Continued |
Entered by HTHRALL1 - emailed contractor, appears missing data layer on plans |
| 05/19/2022 |
COT - ENGR - Signage Final |
Hthrall |
Continued |
Entered by HTHRALL1 - Resubmittal received 5/18/22 |
| 05/04/2022 |
COT - ENGR - Signage Final |
Hthrall |
Partial Approval |
Entered by HTHRALL1 - RE: sign permit review
For: wall signs and change copy on pole sign
At: 8640 E Broadway / Walmart Market
Sign permit: T22OT00319
Reviewer: H. Thrall
Date: 5/4/22
Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC) 600, Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018
1. UDC:
A) Total sign area should be noted on each sign, including change copy panels
2. NEC:
A) provide lock out switch on back of sign at powerpack for safe work on sign
B) indicate where the dedicated breaker panel is located for inspections, ensure labeled
3. OLC:
A) note location of timer (i.e. corporate timer?)
B) clarify if business is 24 hour or if timer needs to be set to midnight
4. IBC:
A) note mounting method to the power pack to the back of the wall (sign A, B, E)
Please return revised plans to Heather.Thrall@tucsonaz.gov
|
| 06/10/2022 |
COT - ENGR - Signage Final |
Hthrall1 |
Continued |
Entered by HTHRALL1 - Your sign package has been authorized for a self-certification inspection. (8 or less signs, and all attached to a building)
Either schedule 09830 as a remote video inspection by leaving your date desired, and then include in the message your phone number and email address
OR
Email PDSDsigninspections@tucsonaz.gov
pictures of the following items to conduct the self-certification inspection:
Elevation view of installed signs to match approved plans
Angled pic of sign lettering to contain the UL sticker in install sticker
Shut off switch
labeled breaker panel - clearly ID signs, ID business location in pic
breaker panel switches in "on" position for signs
Pic of timer - ID shut off time set to, and ID business location in pic
Note that a lock out may be required, depending on location of shut off and location of sign.
|