Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22OT00289

Parcel: 112062810


Addresses:

2402 N CAMPBELL AV


Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Permit Number - T22OT00289

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
04/21/2022 COT - ENGR - Signage Final HThrall Partial Approval Entered by HTHRALL1 - RE: sign review For: wall signs At: 2402 N Campbell Av / Smoke Shop Sign permit T22OT00289 Reviewer: H. Thrall Date: 4/21/22 Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC) 600, Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 Status: Partial Approval - sign area and signs allowed 1. UDC: A) provide landlord permission for sign / raceway use 2. NEC: A) Enlarge diagram for construction please (very hard to read the small font) B) Note the location of the dedicated circuit / breaker panel for inspections C) Unclear where the disconnect switch is for each of the 3 signs, if not on the raceway? D) Note that safety lock outs will be provided for the shut off switches and breaker panel box 3: OLC: A) acknowledged this establishment is open 24 hours, please just note the sign timer location. B) provide note that should business hours change, that timers for signs A & B will be set to midnight curfew, and sign C would be removed E) THIS PROJECT QUALIFIES FOR SELF-CERT INSPECTION 4: IBC: A) Note how many screws provided typical per sign mount to raceway B) provide stronger fasteners for sign mountings to building due to raceway additional weight and list number of fasteners per sign Please send updated plans to Heather.Thrall@tucsonaz.gov
04/29/2022 COT - ENGR - Signage Final HTHRALL Continued Entered by HTHRALL1 - Your sign package has been authorized for a self-certification inspection. (8 or less signs, and all attached to a building) Either schedule 09830 as a remote video inspection by leaving your date desired, and then include in the message your phone number and email address OR Email PDSDsigninspections@tucsonaz.gov pictures of the following items to conduct the self-certification inspection: Elevation view of installed signs to match approved plans Angled pic of sign lettering to contain the UL sticker in install sticker Shut off switch labeled breaker panel - clearly ID signs, ID business location in pic breaker panel switches in "on" position for signs Pic of timer - ID shut off time set to, and ID business location in pic Note that a lock out may be required, depending on location of shut off and location of sign.