Permit: T22OT00256

Parcel: 13405119P


Addresses:

9451 E 22ND ST


Inspection Status: Passed

Inspection History: COT - ENGR - Signage Final

Permit Number - T22OT00256

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Passed

Date Description Inspector Results Comments
05/26/2022 COT - ENGR - Signage Final hthrall1 Approved Entered by HTHRALL1 - resubmittal received / approved 5/26/22
04/26/2022 COT - ENGR - Signage Final Hthrall Partial Approval Entered by HTHRALL1 - RE: sign review For: Starbucks AT: 9451 E 22nd St Sign permit: T22OT00256 Date: 4/6/22 & 4/18/22 (Structural review 4/26/22) Reviewer: H. Thrall Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) PERMIT STATUS: PARTIAL APPROVAL 1. UDC: A). Correct the sign area for sign C. (Should be approx. 42 sqft.) B) Measure frontage from east tenant wall to western drive thru lane edge and revise plan C) Note that all drive thru signs and sign structures shall be setback 1' from face of drive thru cub to leading edge of sign structure per 7.4.6.f.2.a. 2: NEC: A) provide number of circuits for wall signs B) provide number of circuits for detached signs C) provide notation for location of dedicated circuits / breaker panel, provide lock switch on wall signs with shut offs not at sign location 3: OLC: (Ch 4 & 5) A). add note that timer shall be set to curfew of midnight (all signs) B) provide note for location of timer C) provide method for control of dimming 4: IBC: A) welding onsite requires special inspections - clarify any welded signs whether field or shop welds B) no other comments Send revisions to Heather.Thrall@tucsonaz.gov
10/18/2022 COT - ENGR - Signage Final MHERNANDEZ Approved Entered by VVERA1 - APPROVED