Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Complete (Recurring)
Inspection History: COT - ENGR - Signage Final
| Date |
Description |
Inspector |
Results |
Comments |
| 05/04/2022 |
COT - ENGR - Signage Final |
Hthrall1 |
Continued |
Entered by HTHRALL1 - RE: sign review
For: Starbucks
AT: 6291 E Speedway Blvd
Sign permit: T22OT00248
Date: 5/3/22
Reviewer: H. Thrall
Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC)
PERMIT STATUS: PARTIAL APPROVAL
1. UDC:
A) Measure frontage from east to western drive thru lane edges and revise plan to show correct frontage along Speedway Blvd. (developed area of the establishment)
B) Measure frontage from north to south drive thru lane edges and revise plan to show correct frontage along Wilmot Road frontage (developed area of the establishment)
C) Note that all drive thru signs and sign structures shall be setback 1' from face of drive thru cub to leading edge of sign structure per 7.4.6.f.2.a.
2: NEC:
A) provide number of circuits
B) ) provide notation for location of dedicated circuits / breaker panel, provide lock switch on wall signs with shut offs not at sign location
3: OLC: (Ch 4 & 5)
A). add note that timer shall be set to curfew of midnight (all signs)
B) provide note for location of timer
C) provide method for control of dimming (digital menu) ``
4: IBC:
A) welding onsite requires special inspections - clarify any welded signs whether field or shop welds
B) provide engineered plans
Send revisions to Heather.Thrall@tucsonaz.gov
|