Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Complete (Recurring)
Inspection History: COT - ENGR - Signage Final
Permit Number - T22OT00221
Inspection Description - COT - ENGR - Signage Final
Inspection Status - Complete (Recurring)
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/13/2022 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - Your sign package has been authorized for a self-certification inspection. (8 or less signs, and all attached to a building) Either schedule 09830 as a remote video inspection by leaving your date desired, and then include in the message your phone number and email address OR Email PDSDsigninspections@tucsonaz.gov pictures of the following items to conduct the self-certification inspection: Elevation view of installed signs to match approved plans Angled pic of sign lettering to contain the UL sticker in install sticker Shut off switch labeled breaker panel - clearly ID signs, ID business location in pic breaker panel switches in "on" position for signs Pic of timer - ID shut off time set to, and ID business location in pic Note that a lock out may be required, depending on location of shut off and location of sign. |
05/13/2022 | COT - ENGR - Signage Final | Hthrall | Approved | Entered by HTHRALL1 - resubmittal approved 5/13/22 - ok for self-certification inspection |
05/10/2022 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - resubmittal received 5/10/22 |
03/30/2022 | COT - ENGR - Signage Final | Hthrall1 | Continued | Entered by HTHRALL1 - RE: wall sign review At: 4874 S Landing Way, #140 / Alignment Health Sign permit: T22OT00221 Reviewer: H. Thrall Date: 3/30/21 Codes: Unified Development Code 7A Sign Standards, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1. UDC: A)7A.4.1.F - provide written property management permission for the signage. B) UDC 7a.10.2.c. - PAD development in commercial area = sign area allowance is 3 square feet per 1 foot of street frontage. The application shows 24' wide street front (72 sq.ft. maximum) and a proposed total of 75.4 square feet of sign area (distributed between two building elevations). Sign area is exceeded. C) To reduce the sign area proposed, you may break down the logo to count only the positive space, per 7A.6.1: In cases where non-useable space is within the measurement rectangle and the non-useable space is greater than fifty percent of the area of the useable sign area, the measurement rectangles may enclose the useable sign area only. The Logo is a "plus sign" and is currently boxed to include negative space. 2. NEC: A) on plan, note location of breaker panel and that a label to be provided for dedicated sign circuit (for inspections) 3. OLC: 401. A) on plan, note timer to be set to midnight curfew 4. IBC: No comments Note that this proposal qualifies for a self-certification inspection. Instructions will be provided when the permit is issued. Please email revision to Heather.Thrall@tucsonaz.gov |