Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - ENGR - Signage Final
Permit Number - T22OT00220
Inspection Description - COT - ENGR - Signage Final
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | COT - ENGR - Signage Final | Not Ready | ||
05/09/2022 | COT - ENGR - Signage Final | Hthrall | Approved | Entered by HTHRALL1 - Revision sent in 5/6/22. Revision approved 5/9/22 |
05/04/2022 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - RE: sign review For: Starbucks AT: 5353 E Broadway Blvd Sign permit: T22OT00220 Date: 5/3/22 Reviewer: H. Thrall Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) PERMIT STATUS: PARTIAL APPROVAL 1. UDC: A) Measure frontage from east to western drive thru lane edges and revise plan to show correct frontage along Broadway Blvd. (developed area of the establishment) B) Note that all drive thru signs and sign structures shall be setback 1' from face of drive thru cub to leading edge of sign structure per 7.4.6.f.2.a. 2: NEC: A) provide number of circuits for wall signs B) provide number of circuits for detached signs C) provide notation for location of dedicated circuits / breaker panel, provide lock switch on wall signs with shut offs not at sign location 3: OLC: (Ch 4 & 5) A). add note that timer shall be set to curfew of midnight (all signs) B) provide note for location of timer C) provide method for control of dimming (digital menu) `` 4: IBC: A) welding onsite requires special inspections - clarify any welded signs whether field or shop welds B) no other comments C) engineering approved per E. Newcomb Send revisions to Heather.Thrall@tucsonaz.gov |