Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22OT00219

Parcel: 119421830

Inspection Status: Complete (Recurring)

Inspection History: COT - ENGR - Signage Final

Permit Number - T22OT00219

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Complete (Recurring)

Date Description Inspector Results Comments
04/05/2022 COT - ENGR - Signage Final HThrall Continued Entered by HTHRALL1 - Your sign package has been authorized for a self-certification inspection. (8 or less signs, and all attached to a building) Either schedule 09830 as a remote video inspection by leaving your date desired, and then include in the message your phone number and email address OR Email PDSDsigninspections@tucsonaz.gov pictures of the following items to conduct the self-certification inspection: Elevation view of installed signs to match approved plans Angled pic of sign lettering to contain the UL sticker in install sticker Shut off switch labeled breaker panel - clearly ID signs, ID business location in pic breaker panel switches in "on" position for signs Pic of timer - ID shut off time set to, and ID business location in pic Note that a lock out may be required, depending on location of shut off and location of sign.
04/05/2022 COT - ENGR - Signage Final HThrall Approved Entered by HTHRALL1 -
03/24/2022 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - RE: sign review For: wall signs AT: Contact PT / 1360 W Irvington, 260 Sign permit: T22OT00219 Reviewer: H. Thrall Date: 3/24/22 Codes: Unified Development Code 7A. Sign Standards (UDC), National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1) In electrical / mount detail, enlarge font to 12 point - extremely hard to read. 2) correct the address in the application 3) UDC: A. Provide location map view to include street to orient with the building frontage, unclear where you're taking frontage from. (If frontage is correct, sign area proposed is allowed.) 4) NEC: A) Note location of dedicated circuit / breaker panel for inspections B) Note the sign powerpack to be UL listed 5) OLC: A) all sign timers shall be set to a curfew time of midnight - note on plan B) note location of the timer for inspections 6) IBC: A) attachment detail does not seem to match description, as it is a 5" return and no backer panel is shown in the detail. Please provide detail that matches description. B) clarify wall surface to mount signs to, as both appear to have stucco surface and that is also not shown in the attachment detail C) please use stronger fasteners, i.e. thru or anchor bolts for these sign panels, not just screws (again probably different attachment diagram was shown) D) provide mount details for the power pack to the wall Please send revisions to Heather.Thrall@tucsonaz.gov