Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - ENGR - Signage Final
Permit Number - T22OT00088
Inspection Description - COT - ENGR - Signage Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/15/2022 | COT - ENGR - Signage Final | HThrall | Continued | Entered by HTHRALL1 - Revision received, only sign at Gate 2 on West side is illuminated. All others are non-illuminated. Existing walls by others. |
04/07/2022 | COT - ENGR - Signage Final | HThrall | Approved | Entered by HTHRALL1 - Revision approved. |
02/18/2022 | COT - ENGR - Signage Final | HThrall | Continued | Entered by HTHRALL1 - RE: sign review For: monument signs AT: Tucson Electric power entry gates2, 3,4, and 5 (3950 E Irvington) Zone: PAD-34 / based on industrial zoning Sign Permit: T22OT00088 Reviewer: H. Thrall Date: 2/18/22 Codes: Unified Development Code (UDC Chapter 7A Sign Standards) National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (2018). 1) UDC 7A: A) List site frontage along Irvington Rd for calculation of number of freestanding signs B) List site frontage along Swan Rd for calculation of number of freestanding signs C) Dimension the lettering on each sign - on the diagram, and in decimal feet (not inches) D) Sign area per sign is limited to 50 square feet, some signs on application forms exceed the 50 sqft sign area even without the address, double check. E) Addresses do not count toward sign area and can be left off permit application (keep on diagram but do not include in sign area) F) List cumulative total sign area on each diagram G) Note height to top of each sign from grade at base to top of lettering -in decimal feet 2) NEC: A) On sign one - not which letter diagram pertains to which set of lettering. B) Clearly note which letter sets are illuminated per sign structure C) Unclear if signs 2-5 are illuminated or not - conflicting notes. If illuminated, provide all information needed (i.e. volts, amps, circuits, UL, shut off switch locations, circuit location, etc.) If no illuminated ,remove UL and LED references. D) Note location of dedicated circuit for each sign (i.e. in office adjacent, in riser room, etc.) for inspections. Anticipate providing lock outs. 3) OLC: chapters 4 & 5 A) Provide a timer for all illuminated sign structures B) Provide curfew on timer for midnight for any gates that are not 24 hour access (clarify) C) Note maximum of 4400 color temperature for all internally illuminated signs 4) IBC: A) Note walls as existing / built by others B) Is Gate 2 signage missing the top lettering shown on the side view from elevation view? C) show both elevation views of each sign at gate 2, to match site plan that there are two sign Please send revisions to Heather.Thrall@tucsonaz.gov |
05/11/2022 | COT - ENGR - Signage Final | MHERNANDEZ | Continued | Entered by VVERA1 - CN |