Case: T22DV05190

Parcel: 111073120


Addresses:

3161 E TOWNER ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
09/08/2022 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CAL OUT BY TFD: THERE IS FIRE DAMAGE TO THE REAR WOOD FRAMED ADDITION, ALL OF THE INTERIOR WALLS AND CEILING COVERING (SHEETROCK) ARE DAMAGED, TORN, SMOKED AND WET. THE LIVING ROOM HAS DAMAGE TO THE CEILING AND WALL COVERING (PLASTER)THERE ARE MULTIPLE CEILING JOIST WITH SURFACE BURNS. THERE IS A 4 X 4 ROOF CUT OUT IN THE LIVING ROOM, THE HOMES EAVE AREA HAS A 22 FEET SECTION WITH WOOD MEMBERS WHICH HAVE DEEP CRACKS AND SURFACE CHARRING. THE 20 X 30 ATTACHED WOOD FRAMED CARPORT HAS FIRE DAMAGE TO THE FOLLOWING: OVER HALF OF THE ROOF PLANKING, MULTIPLE 2 X 6 RAFTERS, (1) 4 X 8 BEAM, THE 2 X 8 RIDGE BEAM AND MULTIPLE WOOD STUDS AND ONE 4 X 8 POST. THESE MEMBERS HAVE DEEP CRACKS WITH SURFACE CHARRING. THE FRONT DOOR, AND 4 WINDOWS ARE DAMAGED. UNABLE TO INSPECT OTHER ROOMS DUE TO EXCESSIVE STORAGE.

ELECTRICAL: THE HOME HAS MULTIPLE AREAS WITH BURNT AND BARE WIRING WITH DAMAGED ELECTRICAL DEVICES. TEP DID DISCONNECT POWER


PLUMBING: SWG DID PIN METER OFF


MECHANICAL: HEAVY SMOKE THROUGHOUT THE DWELLING

REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY.


INSPECTOR: JUAN VALDEZ
DATE 09-08-2022