Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2022 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL OUT BY TPD: THE VEHICLE HIT THE FRONT OF THE DWELLING'S BEDROOM, AND CAUSED SEVERE DAMAGE TO AN AREA OF 7 FEET IN HEIGHT BY 11 FEET IN WIDTH. THIS AREA HAS MISSING OR BROKING BLOCKS. THE IMPACT ZONE ESTIMATED AT 8 FEET IN HEIGHT BY 12 FEET IN WIDTH. THE AREA HAS MULTIPLE MORTAR JOINT CRACKS. THERE IS ALSO DAMAGE TO THE 4 X 4 WINDOW IN THIS ZONE. THE CORNER OF THE FOUNDATION HAS A 4 INCH CRACK THE EAST EXTERIOR WALL ESTIMATED AT 8 FEET IN HEIGHT AND 6 FEET IN WIDTH. HAS MULTIPLE MORTAR JOINT CRACKS. THERE ARE MULTIPLE BLOCKS ON THE TOP 3 COURSE WHICH HAVE SHIFTED OUTWARD. THERE ARE STRESS CRACKS ON THE INTERIOR EAST AND NORTH WALLS. THE BED WAS PUSHED INTO THE SOUTH WALL CAUSING DAMAGE TO THE SHEET ROCK. THE ADJACENT BEDROOM HAD DAMAGE TO THE SHEETROCK INSIDE THE CLOSET. THERE WERE STRESS CRACKS TO THE INTERIOR NORTH WALL. ELECTRICAL: THERE IS DAMAGED TO ELECTRICAL DEVICES AND CABLES WHICH WERE PULLED FROM THE WALL. THE MAIN DISCONNECT LACKS PROPER LABELING AND IS NOT CODE COMPLIANT. TEP DISCONNECTED POWER PLUMBING: N/A MECHANICAL: N/A REMARKS: PERMIT REQUIRED FOR REPAIRS, THE HOME WAS CONDEMNED, UNSAFE TO OCCUPY. INSPECTOR: BETH TIDWELL DATE 07-24-22 |