Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T22DV03783

Parcel: 120030970

Inspection Status: Passed

Inspection History: COT - ENFC - Code Enforcement - Initial

Date Description Inspector Results Comments
07/05/2022 COT - ENFC - Code Enforcement - Initial VIDAL Approved Entered by VIDAL - The office called that T.F.D. on site with a house fire and the east side not stable. Arrived and all the units have cleared and the fire investigator were on site checking for cause. The fire appears to have started on the outside of the carport and burned into the house into the attic area. The carport was filled with storage on the interior of the carport area including the exterior of the carport. The fire got into the attic and burned, charred or smoked damage on the wood rafters, joist and the 1x planking on the builtup roof system. The drywall was pulled down to check for fire in the attic in several areas. A vent hole was cut on the roof. The electrical was removed at the meter and the gas was aready off due to gas line has failed on holding pressure. The gas line on the wall in the carport and the rear of the house was involved in the fire. The water is off at the meter due to leaks in the water line. The water heater is total lost and the cooler has burned on the roof. The flooring has standing water and the interior of the house has hoarding issues through out the house. Has smoke damage through out. The exterior of the house has storage and trash and debris through out the property with vehicles, tires, tools, motorcycle, boxes and other items. The items around the house on the side of the carport and rear of the house were involved in the fire. The carport wood post have been charred, burned and the fire burned through the 1X planking in several areas on the roof system. The roof on the main house portion has some soft spots due to the amount of burning on the 1X planking and will need to remain off the roof. The owner was not able to secure the house and will be calling the City of Tucson contractor to the site to have the property secured. Called Arcaiden Industries to do the board up of windows, and Biff Baker Fence to have the area by the carport secured from entry. The owner was on site and signed the paperwork on site. The son was staying in the house and will not be able to remain in the house. The son will be staying with the parents. Did do the posting of Do Not Enter on the front window and the rear window. All the metal security doors have been screwed shut. Place City locks on the gates at this time and the owner will be calling the insurance company tomorrow. RV.