| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/29/2022 | INSP - FOLLOW UP CODE ENFORCE | Approved | CLOSE CASE | |
| 05/25/2022 | INSP - FOLLOW UP CODE ENFORCE | Approved | EMERGENCY CALL OUT : THERE ARE 3 RAFTERS WHICH CANTILEVER OUT TO THE 5 FOOT OVERHANG. WHICH HAVE DEEP CRACK WITH SURFACE BURNS. THE DECKING ALSO HAS BURNT AREAS IN THE OVER HANG AREA ESTIMATE AT 5 FOOT BY 20. THE EXTERIOR BLOCK WALLS HAVE CRACKS ESTIMATE AT OVER FEET. THE INTERIOR WALLS THE WESTSIDE OF THE UNIT HAS CRACKS THAT PENETRATE THROUGH THE ADJACENT UNIT. THESE CRACK ARE IN THE MOTOR AND THE BLOCK IN MULTIPLE AREAS AND SPAN OVER 5 FEET. THE NORTH WALL ALSO HAS CRACKS IN THE BLOCKS AND THERE ARE 3 MISSING BLOCKS ABOVE THE STEEL LINTEL. THE WINDOW OPENING AND THE WINDOW IS DAMAGED. THE EASTSIDE WALL IS A WOOD FRAMED WALL WITH SHEETROCK DAMAGE AND THE CEILING ALSO HAS SHEETROCK DAMAGE, THERE IS A 4X4 ROOF CUT OUT. THERE IS SMOKE DAMAGE THROUGHOUT THE UNIT. ELECTRICAL: THE ELECTRICAL DEVICES ARE BURNT WITH BARE AND BURNT WIRING. THE PANEL BOARD HAS CIRCUIT BREAKER LABELED 103 15 AMP, AND THE WALKWAY AND A/C BREAKERS ARE OFF, THIS PANEL IS LOCATED NEXT TO UNIT 116 PLUMBING: SWG DID PIN METER OFF. MECHANICAL: HEAVY SMOKE REMARKS: PERMITS REQUIRED FOR REPAIRS. THE UNIT WAS RE-CONDEMNED INSPECTOR: BETH TIDWELL |