Case: T22DV02185

Parcel: 116131100


Addresses:

701 N AVENIDA FELIZ

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
04/01/2022 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, I FOUND THE AREA AROUND THE STRUCTURE WAS POSSIBLY A RETAINING WALL AS THE STRUCTURES GROUND LEVEL WAS ABOUT THE HEIGHT OF THE SURROUNDING WALL. ON THE EAST SIDE OF THE PROPERTY I FOUND WEEP HOLES APPROX 4-6 INCHES BELOW THE TOP OF THE WALL AND ON THE NORTH SIDE WALL PORTION THERE WERE NO WEEP HOLES SO ANY WATERING OR WATER FROM RAINS WOULD HAVE NO WHERE TO SEEP OUT PUTTING PRESSURE ON THE NORTH SECTION OF WALL. WALL SECTIONS WERE LEANING AT DIFFERENT RATES, SOME SECTIONS 3/4 OF AN INCH OTHERS AN INCH MAYBE A LITTLE MORE. THERE WERE CAP BLOCKS ON THE TOP OF THE WALL SO I WAS UNABLE TO TELL IF THE WALL WAS SOLID GROUTED, AND ALTHOUGH THE WALL IS LEANING IT IS DEFINATELY NOT FALLING DOWN. I TRIED CONTACTING THE OWNER AND LEFT A MESSAGE, SHE DID CALL BACK SHORTLY AFTER. SHE STATED HER AND HER HUSBAND BOUGHT THE HOUSE JUST AS IT WAS, THE WALLS WERE EXISTING. I EXPLAINED TO HER THAT I DID NOT THINK THE WALL WOULD COME DOWN IMMEDIATELY UNFORTUNATELY IF THE WALL CAME DOWN AND HURT SOMEONE, THE WOULD BE LIABLE. I SUGGESTED THAT THEY LOOK INTO MAKING REPAIRS, BUT THAT I ALSO FELT A NOTICE OF VIOLATION WAS NOT WARRANTED. I ALSO EXPLAINED THE ACCESORY STUCTURE CODE THAT WALLS NEEDED TO BE PROPERLY ANCHORED SO AS NOT TO FALL OR COLLAPSE. NO VIOLATIONS AT THIS TIME. COMPLIANCE / CLOSE CASE.