Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T22DV00985

Parcel: 12407087B


Addresses:

801 E 10TH ST


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T22DV00985

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2022 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY TFD: THERE IS FIRE DAMAGE TO THE SECOND STORY WALK WAY AREA. THERE ARE FIVE CANTILEVER 2" X 8" X 5 FOOT RAFTERS, DECKING AND TWO FASCIA BOARDS. THESE WOOD MEMBERS SUPPORT A 2 INCH CONCRETE PAD TO THE WALKWAY DIMENSIONED AT AN ESTIMATED AREA OF 5 FOOT BY 5 FOOT. THERE ARE 8 RAFTERS, DECKING AND FASCIA HAVE SEVERE WOOD ROT. THE SECOND STORY WALKWAY HAS MOVEMENT AND UNSAFE.


ELECTRICAL: N/A


PLUMBING N/A


MECHANICAL: N/A

REMARKS: ENGINEERING AND A PERMIT REQUIRED FOR REPAIRS. THE STAIRS TO THE THE SECOND STORY WALKWAY AND THE END OF THE WALKWAY WAS BARRICADED. VERTICAL SUPPORTS WERE ALSO INSTALLED.