Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T22CM07732

Parcel: 13630138A

Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready
11/22/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required MAS not correctly nailed, anchor bolts at shear walls incorrect, king studs missing at portal framing, remove nails at truss to interior wall connections and install slip clips, lateral bracing missing thruout.
12/01/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed