Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM07676

Parcel: 103081970

Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - T22CM07676

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready
04/27/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready Not ready. Length of shear wall is short south of garage. Add continuous studs underneath girders. Nail every 16" of bottom plate, second floor. Missing blocking on truss. 4/27/2023
05/02/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Approved corrections have been made. 5/2/2023