Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 10/26/2022 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Not Ready |
|
| 03/09/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Not Ready |
3/9/2023 Not ready. Add straps to GLB to post in garage. Add studs 1st floor to support girder second floor. Missing rsp clips. Nail every hole in clips. |
| 03/15/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|