Inspection Status: Not Ready
Inspection History: COT - LCPL - Plumbing Intermediate
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
COT - LCPL - Plumbing Intermediate |
|
Not Ready |
|
| 03/30/2023 |
COT - LCPL - Plumbing Intermediate |
|
Re-inspection required |
March 30th: approved plans not on site, maintain min 1" clearance around B-vent to combustibles, maintain min 10 feet from fresh air intake to vents, support flex duct off sprinkler pipe thru-out, fire block top of mechanical chase, vertical fire blocking can not exceed 10 feet, smoke det is within 3 feet of register |
| 08/22/2023 |
COT - LCPL - Plumbing Intermediate |
|
Re-inspection required |
|
| 08/24/2023 |
COT - LCPL - Plumbing Intermediate |
|
Passed |
|