Permit: T22CM07422

Parcel: 141434840


Addresses:

6646 E VIA OLMEDA


Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - T22CM07422

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Exterior Clips/Sheathing  Not Ready
11/14/2022 COT - RSBU - Exterior Clips/Sheathing  Not Ready missing rsp clips on studs, missing h25 clips on trusses. missing blocking on trusses per truss calcs. add anchor bolt on edges of bottom plates.
11/16/2022 COT - RSBU - Exterior Clips/Sheathing  Passed corrections were made.