10/27/2022 | COT - LCBU - Framing | Not Ready | ||
03/29/2023 | COT - LCBU - Framing | Not Ready | Not ready. Shear wall in wrong place. Add shear wall near closet area 2nd bedroom. Missing rsp clips throughout the home exterior and interior. Missing h25 clips on trusses. Nail off every whole in rsp clips and h25. Add double stud underneath double girder. Add plywood for walkway in attic. 30" minimum of spacing for work area. 3/29/2023 | |
04/05/2023 | COT - LCBU - Framing | Not Ready | Not ready. Per previous notes. 4/5/2023 | |
04/06/2023 | COT - LCBU - Framing | Partial Pass | Partial per intermediates. 4/6/2023 | |
04/21/2023 | COT - LCBU - Framing | Passed |