Permit: T22CM07078

Parcel: 116277640


Addresses:

3170 W TUMAMOC DR


Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Permit Number - T22CM07078

Inspection Description - COT - RSME - Mechanical Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
09/03/2024 COT - RSME - Mechanical Final  Re-inspection required 9/3/24: lock out caps at A/C condenser refrigerant lines, all exterior plastic piping must be UV protected, all plumbing fixtures must be installed at time of final inspection, Arc-fault breaker's required at laundry rooms, handrails at stairs not in at time of inspection, guard rails not installed at time of inspections, water hammer arrester must be installed at dishwasher, b-vent require 1" clearance from combustibles at garage, water heater exhaust must terminate 2' above highest wall portion, grading must be complete, please provide Ladder access. Engineering inspection must pass prior to final, Address must be installed on home at time of inspection.STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
10/07/2024 COT - RSME - Mechanical Final  Re-inspection required 9/3/24: lock out caps at A/C condenser refrigerant lines, all exterior plastic piping must be UV protected, all plumbing fixtures must be installed at time of final inspection, Arc-fault breaker's required at laundry rooms, handrails at stairs not in at time of inspection, guard rails not installed at time of inspections, water hammer arrester must be installed at dishwasher, b-vent require 1" clearance from combustibles at garage, water heater exhaust must terminate 2' above highest wall portion, grading must be complete, please provide Ladder access. Engineering inspection must pass prior to final, Address must be installed on home at time of inspection.STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
10/7/24: lock out caps required at A/C condenser, all plumbing fixtures must be installed at time of final inspection,Arc Fault breaker's required throughout at subpanel, grading not completed, engineering final required prior to final inspection, storm collar required at b-vent.