Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
Permit Number - T22CM07078
Inspection Description - COT - RSME - Mechanical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/17/2025 | COT - RSME - Mechanical Final | Re-inspection required | 01/17/25 1. outlets on exterior east side of home does not have any power. 2. Dishwasher is not secured. 3. Missing your admittance valve in kitchen sink. 4. Anti-tamper caps are still missing on A/C condensers. 5. GFCI upstairs in the laundry is tied to balcony GFCI. 6. Master bedroom downstairs is missing supply, air diffuser, and return air diffuser. OK 7. Extra diffuser in living room, might affect air balance. 8. 6 x 6 diffuser missing in powder room downstairs. 9. Stopped inspection too many issues! please follow your plans, |
|
09/03/2024 | COT - RSME - Mechanical Final | Re-inspection required | 9/3/24: lock out caps at A/C condenser refrigerant lines, all exterior plastic piping must be UV protected, all plumbing fixtures must be installed at time of final inspection, Arc-fault breaker's required at laundry rooms, handrails at stairs not in at time of inspection, guard rails not installed at time of inspections, water hammer arrester must be installed at dishwasher, b-vent require 1" clearance from combustibles at garage, water heater exhaust must terminate 2' above highest wall portion, grading must be complete, please provide Ladder access. Engineering inspection must pass prior to final, Address must be installed on home at time of inspection.STOPPED INSPECTION MORE ITEMS MAY BE ADDED. | |
10/07/2024 | COT - RSME - Mechanical Final | Re-inspection required | 9/3/24: lock out caps at A/C condenser refrigerant lines, all exterior plastic piping must be UV protected, all plumbing fixtures must be installed at time of final inspection, Arc-fault breaker's required at laundry rooms, handrails at stairs not in at time of inspection, guard rails not installed at time of inspections, water hammer arrester must be installed at dishwasher, b-vent require 1" clearance from combustibles at garage, water heater exhaust must terminate 2' above highest wall portion, grading must be complete, please provide Ladder access. Engineering inspection must pass prior to final, Address must be installed on home at time of inspection.STOPPED INSPECTION MORE ITEMS MAY BE ADDED. 10/7/24: lock out caps required at A/C condenser, all plumbing fixtures must be installed at time of final inspection,Arc Fault breaker's required throughout at subpanel, grading not completed, engineering final required prior to final inspection, storm collar required at b-vent. |