Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/30/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | MANNY 520-369-7575 | |
| 06/02/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | 5/30/23 no approved plans on site, fire foam needed on attack, receivers need to be blocked off. 6/2/23: house is locked up, contractor said he cannot fine his approved plans. Not ready. |
|
| 06/06/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required (with fee) | 5/30/23 no approved plans on site, fire foam needed on attack, receivers need to be blocked off. 6/2/23: house is locked up, contractor said he cannot fine his approved plans. Not ready. 6/6/23: no city approved plans provided, pictures of preslab provided but require additional information and proof of 3" clearance from earth in regards to rebar, top plate penetrations must be sealed, HVAC supply must be blocked off on three sides. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
|
| 06/08/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Canceled | 5/30/23 Pre-slab called in after pour of concrete. Will need photos to suffice the work5/30/23 no approved plans on site, fire foam needed on attack, receivers need to be blocked off. 6/2/23: house is locked up, contractor said he cannot fine his approved plans. Not ready. 6/6/23: no city approved plans provided, pictures of preslab provided but require additional information and proof of 3" clearance from earth in regards to rebar, top plate penetrations must be sealed, HVAC supply must be blocked off on three sides. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. 6/8/23: inspection canceled until refee is paid. |
|
| 06/09/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | ||
| 06/13/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Canceled | 5/30/23 no approved plans on site, fire foam needed on attack, receivers need to be blocked off. 6/2/23: house is locked up, contractor said he cannot fine his approved plans. Not ready. 6/6/23: no city approved plans provided, pictures of preslab provided but require additional information and proof of 3" clearance from earth in regards to rebar, top plate penetrations must be sealed, HVAC supply must be blocked off on three sides. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. 5/30/23 Pre-slab called in after pour of concrete. Will need photos to suffice the work5/30/23 no approved plans on site, fire foam needed on attack, receivers need to be blocked off. 6/2/23: house is locked up, contractor said he cannot fine his approved plans. Not ready. 6/6/23: no city approved plans provided, pictures of preslab provided but require additional information and proof of 3" clearance from earth in regards to rebar, top plate penetrations must be sealed, HVAC supply must be blocked off on three sides. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. 6/8/23: inspection canceled until refee is paid. 6/9/23: add 2x6 studs at girder trust, add cut nails at bottom plates in bathroom and closet. 6/13/23: Residential intermediate canceled UNTIL the exterior is lathed and roof is dried in. |
|
| 06/16/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |