Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - T22CM06918
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Not Ready | ||
| 04/14/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Anchor nut washer required to be square plate washers at shear walls SW11 and greater, shearwall edge nailing not per schedule, framing at powder room opening not per plan, block base of stair landings, base plate nailing at 2nd floor shear walls not per schedule | |
| 04/21/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Canceled | 4/21/23: inspection canceled due to work load. | |
| 04/25/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Anchor nut washer required to be square plate washers at shear walls SW11 and greater, shearwall edge nailing not per schedule, framing at powder room opening not per plan, block base of stair landings, base plate nailing at 2nd floor shear walls not per schedule Renail roof 4/21/23: inspection canceled due to work load. 4/25/23: plate washers require a round washer under the anchor nut, 2nd floor shear wall base plate not nailed per schedule,2nd floor shear walls not nailed per schedule |
|
| 04/27/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |