Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM06516

Parcel: 116277070

Inspection Status: Not Ready

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - T22CM06516

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Roof Nailing  Not Ready
09/21/2023 COT - RSBU - Roof Nailing  Re-inspection required 9/21/23:missing roofing on exterior bathroom
09/27/2023 COT - RSBU - Roof Nailing  Re-inspection required not ready. Plans call for I joist 24" o.c. King studs not per plan. Asking for RFI or revision as per built in field. Shear panels are loose throughout addition. Add anchor bolts to breaks at plumbing lines. Add blocking to get proper nailing at edges of sheathing. 9/27/2023
11/06/2023 COT - RSBU - Roof Nailing  Passed 11/6/23: all corrections made plans have been submitted for revision