Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T22CM06472

Parcel: 141434870


Addresses:

6664 E VIA OLMEDA

Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready
03/22/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Not ready. Add nail plates to electrical lines that are less than an 1” 1/4 from edge. Secure electrical lines that have slack. Provide DWV throughout second floor. Add straps to plumbing lines. Space pex lines minimum 12” from any can lights. Secure pex lines in kitchen area. Add blocking to registers going through second floor. Missing blocking at register in kitchen area and laundry room. 3/22/2023
03/23/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Approved. Corrections were made. 3/23/2023