Permit: T22CM06300

Parcel: 12910112C


Addresses:

1416 S CURTIS AV

Inspection Status: Not Ready

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
01/12/2024 COT - RSPL - Plumbing Final  Not Ready
02/08/2024 COT - RSPL - Plumbing Final  Re-inspection required 2/8/24: YWL must be insulated and wrapped for UV protection, Exterior plastic piping must be coated for UV protection, Vacuum breaker missing at hose bibs per plan, water hammer arrestor missing at dishwasher, plumbing under kitchen sink must be of smooth interior, dishwasher drain must be properly installed, water hammer arrestor missing at laundry and fridge, plumbing at lavatory not per code, cleanouts at exterior of units not capped and cut to grade, no ladder for roof access, Panel schedule missing, arc-faults missing, secure dishwasher in place, anti-tip missing at range, bathroom exhaust fans no power, bathroom lights no power, exhaust fan at laundry missing. Light covered under dry-wall.
03/21/2024 COT - RSPL - Plumbing Final  Not Ready
03/27/2024 COT - RSPL - Plumbing Final  Passed