COT - HCBU - Building Progress | Partial Pass | partial approval for stem walls ok to grout to 2nd course and lead walls | ||
05/19/2023 | COT - HCBU - Building Progress | Canceled | 5-19-24: Needed masonry pre grout. | |
05/26/2023 | COT - HCBU - Building Progress | Partial Pass | 5-26-23: Rebar vertical and horizontal reinforcement are in place for the 8' lift. Okay to grout masonry walls. | |
06/02/2023 | COT - HCBU - Building Progress | Partial Pass | pre grout for service reception third lift on west, north walls, parts room 2nd lift south wall. east wall of restrooms 2nd lift | |
10/10/2023 | COT - HCBU - Building Progress | Partial Pass | 5-19-24: Needed masonry pre grout. 5-26-23: Rebar vertical and horizontal reinforcement are in place for the 8' lift. Okay to grout masonry walls. 10/10/23: second floor deck slab ok to pour (reinforcement per plan pg.S103 note 1), roof nailing approved by special inspection. |
|
11/09/2023 | COT - HCBU - Building Progress | Partial Pass | Detail 244 and 242 on page S403 front soffit and parapet wall. East, West and South of building okay to proceed progress areas. 11/9/2023 | |
12/01/2023 | COT - HCBU - Building Progress | Partial Pass | Rooms #102 - #124 plumbing DWV and domestic water lines under pressure and secured. Electrical in walls okay to proceed progress areas. 12/1/2023 | |
12/08/2023 | COT - HCBU - Building Progress | Passed |