Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM05682

Parcel: 123052730


Addresses:

2238 E GRANT RD


Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - T22CM05682

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready
09/19/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 9/19/23: install all windows/doors & siding, block all register boxes, seal top of new wall where attached to existing house, terminate bathroom exhaust to exterior, terminate dryer exhaust to interior, tie all grounds together and install smoke det, install wire to all mini-splits, resubmit new SEALED drawings showing all new plumbing/electric/framing changes to approved plans. The approved plans show a new 200A panel for the addition but does not show where it is attached to structure nor where it is fed from.
09/22/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Not ready, missing doorway at closet per plan, hallway needs to be at 36" at final. Electrical needs to be separated at home runs. Add a 100 amp panel to the addition. Wires going through conduit are tend to over heat. Panel that is existing is at max capacity. Add ground screws to metal boxes. Dryer duct needs to be installed. 9/22/2023
10/04/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Corrections were made. Approved. 10/4/2023