Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - T22CM05455
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2022 | COT - RSBU - Exterior Clips/Sheathing | Not Ready | ||
01/03/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
12/14/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | P2 shear walls missing nails at top of boards, missing anchor bolts at right side of house, missing truss calcs. | |
12/21/2023 | COT - RSBU - Exterior Clips/Sheathing | Partial Pass | P2 shear wall still missing nails at top of board. Ok to proceed. Check at intermediate. |