Inspection Status: Not Ready
Inspection History: COT - RSEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
COT - RSEL - Electrical Final |
|
Not Ready |
|
| 08/15/2023 |
COT - RSEL - Electrical Final |
|
Re-inspection required |
Bathroom/powder room must be gfci protected, complete outlet wiring in kitchen, add gfci outlet receptacle to right side of kitchen sink per 2018 IRC E3901.4. |
| 08/17/2023 |
COT - RSEL - Electrical Final |
|
Re-inspection required |
Add gfci outlet receptacle within 2' of the right side of kitchen sink per 2018 IRC E3901.4.1. |
| 08/23/2023 |
COT - RSEL - Electrical Final |
|
Passed |
Approved. Corrections were made. 8/23/2023 |