Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 10/26/2022 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Not Ready |
|
| 10/20/2022 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
SCARRAZCO |
Not ready for Inspection |
Entered by NGARCIA3 - Not ready. Missing titan bolts behind shear wall in garage. |
| 10/13/2022 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
SCARRAZCO |
Not ready for Inspection |
Entered by NGARCIA3 - Not ready. Missing anchor bolts behind shear walls. Missing hangers underneath stairway. Secure all bottom plates. Missing clips on trusses. Add 2x4 to support double girder in gap. Secure bottom plates on top floor. Shear wall should not be less than 16" |
| 11/02/2022 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
corrections have been made. |